English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Faigh Luachan Meandarach
Leave Your Message
PH6101-2A2B
Athsheachadáin Sábháilteachta Córais Mheicniúil
Catagóirí Táirgí
Táirgí Réadmhaoine

PH6101-2A2B

Feidhmeach i gCnaipí Stop Éigeandála, Geataí Sábháilteachta, ionchur comharthaí DO

    Forbhreathnú

    Is modúl rialaithe athsheachadáin sábháilteachta é PH6101-2A2B atá oiriúnach do chnaipí stad éigeandála, ionchuir lasc rialaithe dorais sábháilteachta, le 2 theagmháil aschuir sábháilteachta oscailte de ghnáth (NO) agus 2 theagmháil aschuir chúnta dúnta de ghnáth (NC) le haghaidh athsheachadáin sábháilteachta. Tacaíonn sé le hoibriú aonchainéal agus déchainéal, athshocrú láimhe nó uathoibríoch, agus tá feidhm monatóireachta gearrchiorcad idirchainéal aige.

     

    Sonraí teicniúla

    Saintréithe an tsoláthair cumhachta
    Soláthar cumhachta 24V DC/AC
    Tomhaltas reatha ≤90mA (24V DC)
    ≤240mA (24V AC)
    Caoinfhulaingt voltais 0.85~1.1
    Minicíocht AC 50Hz~60Hz
    Saintréithe ionchuir
    Friotaíocht sreinge ≤ 15 Ω
    Reatha ionchuir ≤50mA (24V DC)
    Gléas ionchuir Cnaipí Éigeandála, Geataí Sábháilteachta, Comharthaí DO
    Saintréithe aschuir
    Líon na dteagmhálaithe 2NO+2NC
    Ábhar teagmhála AgSnO2+0.2 μmAu
    Cineál teagmhála Treoir éigeantach
    Cosaint fiús teagmhála 10A gL/gG, NEOZED (teagmháil oscailte de ghnáth)
    6A gL/gG, NEOZED (teagmháil dúnta de ghnáth)
    Cumas lasctha AC-15,5A/230V; DC-13,5A/24V
    Saolré meicniúil níos mó ná 10⁷ uair
    Saintréithe ama
    Moill lasctha
    Athshocrú uathoibríoch ≤300ms
    Athshocrú láimhe ≤150ms
    Dífhuinneamhú moillithe
    Oibríocht stad éigeandála ≤30ms
    Teip cumhachta ≤100ms
    Am téarnaimh
    Oibríocht stad éigeandála ≤30ms
    Teip cumhachta ≤100ms
    Briseadh gearr soláthair 20ms
    deimhniú sábháilteachta
    Leibhéal Feidhmíochta (PL) Comhlíonann PLe EN ISO 13849
    Catagóir Slándála (Cat.) Comhlíonann Cat.4 EN ISO 13849
    Am Tasca (TM) 20 bliain i gcomhréir le EN ISO 13849
    Clúdach diagnóiseach (DC/DCavg) Comhlíonann 99% EN ISO 13849
    Leibhéal Ionracais Sábháilteachta (SIL) Comhlíonann SIL3 IEC 61508, IEC 62061
    Caoinfhulaingt Lochtanna Crua-earraí (HFT) 1 i gcomhréir le IEC 61508, IEC 62061
    Codán teipe sábháilte (SFF) Comhlíonann 99% de na caighdeáin IEC 61508, IEC 62061
    Dóchúlacht teipe guaiseach (PFHd) Comhlíonann 3.09E-10/u IEC 61508, IEC 62061
    Catagóir Stop 0 i gcomhréir le EN 60204-1
    10% de mheánlíon na dtimthriallta teipe guaiseacha i gcomhpháirteanna (B10d)  
    DC13, Ue = 24V Ie 5A 2A 1A
    Timthriallta 300,000 2,000,000 7,000,000
    AC15, Ue = 230V Ie 5A 2A 1A
    Timthriallta 200,000 230,000 380,000

     

    Saintréithe comhshaoil
    Comhoiriúnacht leictreamaighnéadach i gcomhréir le EN 60947, EN 61000-6-2, EN 61000-6-4
    Minicíocht chreathadh 10Hz ~ 55Hz
    Aimplitiúid chreathadh 0.35mm
    Teocht chomhthimpeallach -20 ℃~+60 ℃
    Teocht stórála -40 ℃~+85 ℃
    Taiseachas coibhneasta 10% go 90%
    Airde ≤ 2000m
    Saintréithe inslithe
    Imréiteach leictreach agus achar creepage i gcomhréir le EN 60947-1
    Leibhéal róvoltais Tríú
    Leibhéal truaillithe 2
    Leibhéal cosanta IP20
    Neart inslithe 1500V AC, 1 nóiméad
    Voltas inslithe rátáilte 250V AC
    Voltas impulse rátáilte 6000V (1.2/50us)

     

    Toisí seachtracha

    PH6101-2A2B(2).png

    Léaráid Bhloc Feidhmiúil

    PH6101-2A2B.png

    Feidhmchlár tipiciúil

    PH6101-2A2B(1).png

    Léaráid sreangaithe

    (1) Glacann sreangú na hionstraime críochfort nasctha pluggable;
    (2) Ní mór achar trasghearrthach copair bhog an tsreinge taobh ionchuir a bheith níos mó ná 0.5mm2, agus ní mór don taobh aschuir a bheith níos mó ná 1mm2;
    (3) Tá fad nochta an tsreinge thart ar 8mm, atá faoi ghlas le scriúnna M3;
    (4) Ní mór go leor nasc cosanta fiús a sholáthar sna teagmhálacha aschuir;
    (5) Ní mór don seoltóir copair teocht chomhthimpeallach 75 ℃ ar a laghad a sheasamh;
    (6) Is féidir le scriúnna críochfoirt míoibriú, téamh, etc. a chur faoi deara. Dá bhrí sin, déan iad a theannú de réir an chasmhóiminte shonraithe. Chasmhóimint teannaithe scriú críochfoirt 0.5Nm.

    Sreangú.png

    Suiteáil

    Ba chóir athsheachadáin sábháilteachta a shuiteáil i gcaibinéid rialaithe a bhfuil leibhéal cosanta IP54 ar a laghad acu. Idir an dá linn, ba chóir go mbeadh an suiteáil agus an úsáid i gcomhréir le forálacha ábhartha GB 5226.1-2019 "Sábháilteacht Mheicniúil agus Leictreach - Trealamh Meicniúil agus Leictreach - Cuid 1: Coinníollacha Teicniúla Ginearálta".
    Tá ráillí treorach DIN35mm suiteáilte le gach athsheachadán sábháilteachta sraith PH6101-2A2B. Seo a leanas na céimeanna suiteála
    (1) Clampáil barr an ionstraime ar an ráille treorach;
    (2) Brúigh foirceann íochtarach an uirlis isteach sa ráille treorach.

    Suiteáil.png

    Díchóimeáil

    Cuir scriúire (leithead na lanna ≤ 6mm) isteach sa ghlais miotail ag foirceann íochtarach phainéal na n-ionstraimí;
    Brúigh an scriúire suas agus próc an laiste miotail anuas;
    Tarraing painéal na n-ionstraimí suas agus amach as an ráille treorach.

    Dí-chomhthionól.png

    Cothabháil

    (1) Seiceáil go rialta le do thoil an bhfuil feidhm sábháilteachta an athsheachadóra sábháilteachta i riocht maith, agus an bhfuil comharthaí ann go bhfuil an ciorcad nó an bunleagan curtha as feidhm nó seachbhóthar déanta air;
    (2) Lean na rialacháin sábháilteachta ábhartha agus oibrigh de réir na dtreoracha sa lámhleabhar treoracha seo, nó d’fhéadfadh timpistí marfacha nó cailliúint pearsanra agus maoine a bheith mar thoradh air;
    (3) Rinneadh cigireacht agus rialú cáilíochta dian ar na táirgí sula bhfágann siad an mhonarcha. Má fhaigheann tú amach nach bhfuil na táirgí ag obair i gceart agus má cheapann tú go bhfuil locht ar an modúl inmheánach, déan teagmháil leis an ngníomhaire is gaire nó déan teagmháil dhíreach leis an líne chabhrach tacaíochta teicniúla.
    (4) Laistigh de shé bliana ón dáta seachadta, déanfaidh Pinghe aon fhadhbanna cáilíochta táirge le linn gnáthúsáide a dheisiú saor in aisce.

     

    Aird

    Deimhnigh le do thoil an bhfuil pacáistiú an táirge, samhail lipéad an táirge, agus na sonraíochtaí ag teacht leis an gconradh ceannaigh;
    Sula ndéanann tú athsheachadáin sábháilteachta a shuiteáil agus a úsáid, léigh an lámhleabhar seo go cúramach;
    Má tá aon cheist agat, déan teagmháil le Líne Chabhrach Tacaíochta Teicniúla Beijing Pinghe ag 400 711 6763;
    Ba chóir an t-athsheachadán sábháilteachta a shuiteáil i gcomh-aireachta rialaithe a bhfuil leibhéal cosanta IP54 ar a laghad aige;
    Tá an ionstraim faoi thiomáint ag soláthar cumhachta 24V, agus tá cosc ​​​​dian ar úsáid soláthar cumhachta AC 220V;