Betawi
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Dapetin penawaran instan
Leave Your Message
PHG-12TF-288/PHG-22TF-2828
Masukan Digital
Kategori Produk
Produk Unggulan

PHG-12TF-288/PHG-22TF-2828

Isolator Sinyal Masukan Digital
PHG-12TF-288 1 masukan dan 2 keluaran
PHG-22TF-2828 2 masukan dan 2 keluaran

Masukan: Ganti kontak/saklar kedekatan
Keluaran: Transistor

    Tinjauan umum

    Isolator sinyal keluaran transistor masukan beralih mengubah sinyal masukan dari kontak saklar atau saklar kedekatan menjadi keluaran transistor melalui isolasi. Fungsi deteksi kesalahan garis ditampilkan oleh lampu LED di bagian atas modul. Saklar modul dipake buat milih fase saluran dan apakah fungsi deteksi kesalahan jalur dibutuhin.

    Produk ini perlu dinyalain secara independen, dan catu daya, terminal input dan output diisolasi.

     

    1

     

    Masukan
    Sinyal masukan Ganti kontak/saklar kedekatan
    Tegangan pasokan sensor Sekitar 8V
    Rentang frekuensi masukan ≤5kHz
    Karakteristik masukan/keluaran:
    Arus masukan di tempat >2.1mA, outputnya ditutup, nunjukin ON;
    Kalo
    Kontrol beralih antara fase terbalik dan fase normal dari keluaran ec Pas saklar dial K1, K3 ada di sisi "ON", keluaran transistor ec ada di fase terbalik
    Pas saklar dial K1、K3 ada di sisi "OFF", ec keluaran transistor ada di fase normal
    Pas saklar dial K2、K4 ada di sisi "ON", sirkuit milih fungsi alarm LFD yang nunjukin lampu merah.
    Keluaran
    Sinyal keluaran Transistor
    Karakteristik keluaran transistor tipe NPN emitor atau kolektor keluaran sirkuit terbuka
    Kemampuan nyetir Arus keluaran ≤ 20mA (1.2k Ω), arus internal maksimum 100mA, dilengkapi dengan perlindungan arus rangkaian pendek
    Parameter dasar
    Tegangan pasokan 20~35VDC
    Konsumsi daya
    Indikator LED Hijau: Indikator daya
    Kuning: Transistor keluaran dalam keadaan kerja normal
    Merah: indikasi LFD, alarm kesalahan jalur
    Parameter suhu Suhu kerja: -20°C ~ +60°C,
    Suhu penyimpanan: -40°C ~ +80°C
    Kelembaban relatif 10%~95% RH kagak ada kondensasi
    Kekuatan isolasi ≥2000VAC/min (antara input/output/catu daya)
    Ketahanan isolasi 100MΩ (500VDC)(antara masukan/keluaran/catu daya)
    Kecocokan elektromagnetik GB/T 18268(IEC 61326-1)
    MTBF 80000h
    Persyaratan kawat Penampang ≥ 0.5mm2; Kekuatan isolasi ≥ 500V
    Peralatan lapangan yang berlaku Peralatan lapangan seperti kontak kering atau masukan saklar kedekatan tipe NAMUR yang sesuai dengan standar DIN19234



    phg-12tf-288-1

    Catatan: 1. PHG-12TF-288 kagak termasuk input 2 bagian.
    2. Catu daya dari rel listrik adalah fungsi opsional. Pengguna perlu nentuin mode catu daya pas mesen. Tolong liat lampiran di halaman 89.

    phg-12tf-288-2-2

    Deteksi Kesalahan Garis

    Pengguna bisa milih sisi "ON" dari saklar di bagian atas modul buat ngaktifin fungsi deteksi kesalahan dan nunjukin alarm lewat lampu LED merah. Arus masukan di lokasi>7mA, alarm rangkaian pendek (SC); Arus masukan di lokasi



    Unduh_file
    PHD-11TC-33A-23


    Unduh_file
    PHG-12TF-288 PHG-22TF-2828