- Terminal Board
- Gin ma gengo gwok ma ki poko
- Gin ma poko lanyut
- Jami ma gwoko kom ki i mac
- Jami ma gwoko kuc
- I/O Modules ma ki poko gii ma ryek
- doggola ma ryek
- Jami ma ki lwongo ni Industrial Data Optical Transceivers
- Jami ma ki lwongo ni Dew Point Analyzers ma tye i intanet
- Jami ma ki tiyo kwede me nongo ngec
- HART gin ma loko ngec
0102030405
PHL-TX24-P4-X EX Field Instrument Surge Protective Devices
GIN MA KI TIMO
| Ngec ma mako jami ma mako tic | Waya aryo | waya adek | waya angwen |
| Rated operating voltage Un | 24V | 24V | 24V |
| Teko ma malo loyo me tic Uc | 35V | 35V | 35V |
| Nominal operating current IL | 10kA | 10kA | 10kA |
| Gin ma ki lwongo ni discharge current In (8 / 20μs) | 20kA | 20kA | 20kA |
| Kit ma ki cwalo kwede mac ma malo (8 / 20μs) | 20kA | 20kA | 20kA |
| Lightning surge current limp (10 / 350μs) | 2.5kA | 2.5kA | 2.5kA |
| wel mac ma lyel (10 / 350μs) | 5kA | 7.5kA | 10kA |
| Gwoko teko ma malo (8 / 20μs) line-to-line | 60V | 60V | 60V |
| Gwoko teko ma malo (1KV / μs) line me cito i ngom | 600V | 600V | 600V |
| Cawa me gamo lapeny | 1ns | 1ns | 1ns |
| Kit me gwok ma kimiyo ki gang (ma rwate ki IEC 60529) | IP 67 | IP 67 | IP 67 |
| Jami me ot | 304 nyonyo ma pe mako nyal | 304 nyonyo ma pe mako nyal | 304 nyonyo ma pe mako nyal |
| Kit ma ki yubu kwede lok | Tit ka itye ka lwongo | Tit ka itye ka lwongo | Tit ka itye ka lwongo |
| Kit me temo | GB/T 18802.21 / IEC61643-21 | GB/T 18802.21 / IEC61643-21 | GB/T 18802.21 / IEC61643-21 |
| Karatac me gengo mwoc | EX ki II C T4-T6 Gb | EX ki II C T4-T6 Gb | EX ki II C T4-T6 Gb |
| EX ia II C T4-T6 Ga | EX ia II C T4-T6 Ga | EX ia II C T4-T6 Ga | |
| rwom me lyeto ma tye ka tic | —40℃~ +80℃ | —40℃~ +80℃ | —40℃~ +80℃ |
cal

"*" ma tye i namba me model nyutu kit ma ki yubu kwede, ma omyera ki lok iye ka ki tye ka keto: I:M20X1.5 N:1/2”NPT G:G1/2”
cal ma ki nyutu

cal ma ki goyo ki rwom

Ngec: Gin ma ki keto me kubbe kwede tye 15m2, borre tye 250mm ki waya ma tye ki dul mapol, tek i kom acid ki abrasion.
Kwac
Gin ma ki lwongo ni Field Instrument Surge Protective Device ni ber me gwoko jami ma pat pat, medo ki:
1.2-waya, 3-waya, ki 4-waya ma cwalo lok:Jami ma cwalo lok ni ki tiyo kwede me pimo jami ma pat pat calo rwom me lyeto, lyeto, rwom, ki jami mukene, i kabedo ma twero kelo peko.
2.Thermocouples (TC) ki Resistance Temperature Detectors (RTD):Jami ma kwanyo lyeto ni pol kare ki tiiyo kwede i yub me tic me pimo lyeto maber ki maber.
3.Ka lok ma calo RS485, RS232, ki RS422:Jami eni ki tiiyo kwede me lok i kin jami ma pat pat, me neno ni jami ni rwate ki jami ma pat pat.
4.Flow meters:Flow meters ki tiyo kwede me pimo rwom me mol pa pii onyo yamo i paip onyo jami ma ki tiyo kwede, ma miyo ngec ma pire tek pi gwoko ki neno tic.
5.Electromagnetic valves:Valve magi gi gwoko mol pa pii i yub me tic ki gi pire tek me doro wot pa pii onyo yamo i paip.