- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
PHL-T24-L3-EX
The following features describe this intrinsic safety surge prevention device for 24 volt systems:
12.4 mm very thin design The design is incredibly space-efficient, making it ideal for locations with limited room. It is also simple to install in control cabinets or other equipment.
Because the surge protection module is hot swappable, operating safety and convenience are increased because there is no need to shut down the system when performing maintenance or replacing the protection module.
Single-use detection: The surge protection module can be tested independently, which facilitates the prompt identification and resolution of issues and guarantees the system's continuing operation.
Applicable to a wide range of signal circuits: offers efficient surge protection for a wide range of signal circuits, including RS232, DI, DO, AO, and AI (analog input, digital output).
Grounding using a metal DIN35 guide rail: Enhancing the stability and safety of the system is possible by grounding through a metal guide rail, which guarantees the dependability of equipment grounding.
SPECIFICATIONS
Technical data |
Two-wire |
Three-wire |
Four-wire |
Rated operating voltage Un |
24V |
24V |
24V |
Maximum operating voltage Uc |
32V |
32V |
32V |
Nominal operating current IL |
600mA |
600mA |
600mA |
Nominal discharge current In (8 / 20μs) |
10kA |
10kA |
10kA |
Maximum discharge current (8 / 20μs) |
20kA |
20kA |
20kA |
Lightning surge current limp (10 / 350μs) |
2.5kA |
2.5kA |
2.5kA |
Total lightning surge current (10 / 350μs) |
5kA |
7.5kA |
10kA |
Protection voltage Up (8 / 20μs) line-to-line / line to ground |
60V/600V |
60V/600V |
60V/600V |
Protection voltage Up (1KV / μs) line to line / line to ground |
40V/600V |
40V/600V |
40V/600V |
Bandwidth (-0.5dB) |
10MHz |
10MHz |
10MHz |
Response time |
1ns |
1ns |
1ns |
Series resistance (per line) |
1Ω |
1Ω |
1Ω |
Leakage current |
<10μA |
<10μA |
<10μA |
Degrees of protection provided by enclosure (in line with IEC 60529) |
IP 20 |
IP 20 |
IP 20 |
Housing material / Flame retardant grade (the UL94) |
PC/V0 |
PC/V0 |
PC/V0 |
Test standard |
GB/T 18802.21 / IEC61643-21 |
GB/T 18802.21 / IEC61643-21 |
GB/T 18802.21 / IEC61643-21 |
Explosion-proof certifications |
EX ia II C T4-T6 Ga |
EX ia II C T4-T6 Ga |
EX ia II C T4-T6 Ga |
Working temperature range |
—40 ℃ ~ +80 ℃ |
—40 ℃ ~ +80 ℃ |
—40 ℃ ~ +80 ℃ |